Busduct

Busbar Trunking System, first introduced in 1932, solving the automation industries needs for flexible power distribution system.

Since then, Busbar Trunking System had evolved from Air Insulated design to today compact series “Sandwich design” and incorporating monitoring & control system in load distribution. The versatility of Busbar Trunking System design not only serves high-amperage application efficiently in terms of energy loss, it also provides high productivity in the implementation on site.

Today, Busbar Trunking System is widely used in all segments of development:
(1) Data Centre
(2) Industrial
(3) Commercial
(4) Residential
(5) Healthcare
(6) Infrastructure

Recognizing the needs for more efficient & flexible solution, Tai Sin Electric Limited, a renowned Cable & Wire manufacturer & specialist in Low Voltage Power Distribution system, developed a new range of Low Voltage Busbar Trunking System which is designed and tested in Singapore.

Data Centers
• Service Continuity
• Halogen-free
• Flexibility To Evolve/Expand
• Customizable Colour

Industrial Areas
• Service Continuity
• Flexibility To Evolve/Expand
• Halogen-free
• Low Voltage Drop
• Low Maintenance Frequency

Commercial Areas
• Service Continuity
• Flexibility To Evolve/Expand
• Halogen-free
• Low Voltage Drop
• Low Maintenance Frequency

Residential Areas
• Service Continuity
• Halogen-free
• Low Maintenance Frequency

Healthcare Sectors
• Service Continuity
• Low Electromagnetic Field Emission
• Halogen Free
• Low Voltage Drop

Infrastructure
• Service Continuity
• Model Availability
• Halogen-free
• Low Voltage Drop
• Low Maintenance Frequency
• Low Electromagnetic Field Emission

Tai Sin T Line I series Busbar Trunking System conforms to IEC 61439-6. Full type test certification (IEC61439) for each and every ampere rating of Busbar Trunking System.

Conductors

All our products are high density and conductivity. Copper conductor has minimum purity of 99.95% with conductivity of >100% IACS while aluminium has minimum purity of 99.7% with conductivity>61% IACS. It is fabricated through a sophisticated thermal compression process which involves application of tremendous heat under high pressure. It can be tinned or silver-plated with epoxy powder coated as insulation giving 100% water and chemical resistance. Optional specifications can be designed and fabricated to customer requirement.

Advantage of using our conductor
• High electrical conductivity
• Low impurity
• Excellent fatigue resistance
• High thermal conductivity
• High mechanical strength
• Outstanding corrosion resistant

Epoxy

Our Epoxy System is the 3rd generation with own formulation. The class H-180°C standard epoxy coating provides 100% waterproofing and high mechanical strength. It has been tested in accordance with IEC 61439-1 and IEC 61439-6.

Advantages of using epoxy coating as insulations
• Designed to withstand glitch and spikes in electrical system
• Designed to cater for expansion and contraction during peak and off-peak hours
• Capable of withstanding heat shock
• High reliability under static conditions
• High mechanical strength against impact
• High thermal conductivity
• Water and chemical resistant

Other Insulation Type

Besides epoxy insulation, we also provide other classes of insulation as below:
• Class B – It consists of two layers of Mylar (Polyester Film) which resists temperature up to 130°C.
• Fire Rated – It consists of 1 layer of Mylar (Polyester Film) and 2 layers of Mica (mineral silicate sheet) which resist temperature up to 900°C.

Other Insulation Type

In order to overcome extreme rugged conditions at site, the new Busbar Trunking System joint has been designed precisely and manufactured using the highest quality of materials to minimize all possible problems and enhance system performance. This special design provides outstanding features as follows:
• Incorporates a 5mm thermal expansion and movement at every point.
• Allow ±15mm of lateral adjustment (total 30mm) to correct site measurement inaccuracy.
• Able to tilt an angle of ±5° (total 10° along a single axis).
• Bolt and nuts can be stainless steel, galvanized or chromed black high tensile steel.
• Degree of protection of IP40-IP66.
• Easy installation and removal at any joint in a run without disturbing the two adjacent Busbar Trunking System sections.
• Water/chemical resistance BMC insulation plates

1. Joint Bolt
2. Joint Backing Plate
3. Joint Earth Bar
4. Joint End Insulator
5. Joint Conductor Bar
6. Joint Phase Insulator
7. Belleville Disc
8. Nylon Lock Nut
9. Fiber Tube

Tap-off Units (Plug-in Units)

Tap-off unit with moulded case circuit breaker (MCCB) or fused-switch breakers of various current ratings are available to cater for most installations. Maximum 5 tap-off units per side can be installed, total 10 nos per length of 3m busbar subject to the size of MCCBs.
• All tap-off unit are designed with interlocking safety features to prevent removal when tap-off unit in ‘On’ position.
• When tap-off unit cover is open, automatically, MCCB cannot be turned ‘On’.

IP Busbar Trunking System

Electrical Specifications

Resistance, Reactance, Impedance and Voltage Drop